Inscrivez-vous maintenant pour un meilleur devis personnalisé!

Nouvelles chaudes

Huawei S6730-S24X6Q: Advanced Ethernet Switch for Modern Networks

Jan, 23, 2025 Hi-network.com

s6730-s24x6q

The Huawei | S6730-S24X6Q is a high-performance Ethernet commutateur designed to meet the demands of modern data centers and campus networks............. It offers advanced features and robust specifications to ensure efficient and reliable network operations.

Key Features

▪ High Port Density: 24 x 10 Gigabit SFP+ ports and 6 x 40 Gigabit QSFP+ ports.
▪ High Switching Capacity: Up to 2.4 Tbit/s to handle heavy traffic loads.
▪ Advanced Layer 2 and Layer 3 Features: Supports comprehensive protocols for versatile network configurations.
▪ Stacking Capability: Supports stacking through 10GE SFP+ and 40GE QSFP+ ports for simplified management.
▪ Energy Efficiency: Designed for low power consumption to reduce operational costs.
▪ Comprehensive Security: En dehorsers features like ACLs, 802.1X authentication, and DHCP snooping for enhanced network protection.
▪ Qualité de Service (QoS) voir aussi:: Provides traffic classification and prioritization to ensure optimal performance for critical applications.
▪ Flexible Management: Supports various management methods, including CLI, web-based management, and SNMP.
▪ High Reliability: Features redundant power supplies and hot-swappable fan modules for continuous operation.
▪ Virtual Extensible LAN (VXLAN): Supports VXLAN L2 and L3 gateways for network virtualization.

Spécifications techniques

Ports: 24 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports.
Switching Capacity: 2.4 Tbit/s.
Forwarding Performance: 480 Mpps.
Dimensions (H x l x p): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.).
Poids (avec emballage): 8,9 kg (19,62 lb).
Power Supply: Supports dual AC and DC power modules.
Operating Temperature: -5°C à +45°C (23°F à 113°F) à une altitude de 0 à 1800 m (0 à 5906 pieds).
Operating Humidity: 5% à 95%, sans condensation.
Stacking Support: Up to 16 physical ports for stacking using 10GE SFP+ and 40GE QSFP+ ports.
Airflow Direction: Air intake from front, air exhaustion from rear (front-to-rear).

Port Details

10GE SFP+ Ports: 24 ports supporting various optical modules and cables, including GE module optiques, 10GE SFP+ optical modules, and high-speed copper cables.
40GE QSFP+ Ports: 6 ports compatible with QSFP+ module optiques and high-speed copper cables. Note: A QSFP+ optical port cannot be split into four 10GE ports.

Puissance et refroidissement

The S6730-S24X6Q supports dual hot-swappable power modules, allowing for AC and DC inputs:
AC Input: 100 V AC to 240 V AC, 50/60 Hz.
High-Voltage DC Input: 240 V DC.
DC Input: -48 V DC to -60 V DC.
Maximum Power Consumption: 249 W.
Typical Power Consumption: 135 W.
Fan Modules: Four pluggable fan modules with front-to-rear airflow design for efficient cooling.

Stacking and Virtualization

The switch supports stacking through its 10GE SFP+ and 40GE QSFP+ ports, allowing multiple switches to function as a single logical unit for simplified management and enhanced scalability. It also supports VXLAN L2 and L3 gateways, enabling network virtualization for flexible and efficient network designs.


Caractéristiques de sécurité

The S6730-S24X6Q offers comprehensive security features to protect network integrity:
Access Control Lists (ACLs): Permit or deny traffic based on predefined security policies.
802.1X Authentication: Ensures that only authorized users can access the network.
DHCP Snooping: Prevents unauthorized DHCP servers from distributing IP addresses.
IP Source Guard: Blocks packets with spoofed IP addresses.
Dynamic ARP Inspection (DAI): Protects against ARP spoofing attacks.

Quality of Service (QoS)

The switch provides advanced QoS features to ensure optimal performance for critical applications:
Traffic Classification: Identifies and classifies incoming traffic based on various parameters.
Traffic Policing and Shaping: Controls the rate of traffic sent or received on a network interface.
Priority Queuing: Ensures that high-priority traffic is transmitted first.
Congestion Management: Implements mechanisms to prevent and manage network congestion.

Gestion et Maintenance

The S6730-S24X6Q supports various management methods for ease of use:
Command-Line Interface (CLI): Provides a text-based interface for configuration and monitoring.
Web-Based Management: En dehorsers a graphical user interface accessible through web browsers.


Huawei CloudEngine S6730-S24X6Q Switches

Huawei All Les séries Switches New and Used

For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com  (Email: [email protected])



S6730-S24X6Q (02353AJW/02353AJW-001/02353AJW-003/02353AJW-004)

Version Mapping

Table 4-227 lists the mapping between the S6730-S24X6Q chassis and software versions.

Table 4-227 Version mapping

Series

modèle

Version du logiciel

S6730-S

S6730-S24X6Q

02353AJW: V200R019C00 and later versions

02353AJW-001: V200R020C10 and later versions

02353AJW-003: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.)

02353AJW-004: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

Remarque:

V200R021C01 is not supported.

Some models cannot be downgraded due to component upgrade. Therefore, you are advised to run the display system-software information command (supported in V200R021C00 and later versions) to check the software versions supported by the device before performing a downgrade.

Appearance and Structure

Figure 4-94 S6730-S24X6Q appearance

1

Vingt-quatre ports 10GE SFP+

Modules et câbles applicables:
  • GE optical module

  • Module optique GE-CWDM

  • GE-DWDM module optique

  • GE module cuivre

  • 10GE SFP+ module optique (OSXD22N00 non pris en charge)

  • 10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)

  • 10GE-CWDM module optique

  • 10GE-DWDM module optique

  • 1 m, 3 m, 5 m et 10 m SFP+ câbles cuivre haute vitesse

  • Câbles SFP+ AOC de 3 m et 10 m

  • Câbles de 0.5 m et 1.5 m SFP+ dédiés à la pile (pris en charge par les 16 derniers ports SFP+ et utilisés uniquement pour l’empilement sans configuration)

2

Six 40GE QSFP+ ports optiques

Modules et câbles applicables:
  • QSFP+ optical module

  • 1 m, 3 m et 5 m QSFP+ à QSFP+ câbles cuivre haute vitesse

  • 10 m QSFP+ à QSFP+ câble AOC

  • 2 m QSFP28 câble de pile dédié (pris en charge dans V200R020C10 et versions ultérieures)

  • QSFP28 optical module (supported in V200R024C00 and later versions, need a license loaded)

  • 1 m QSFP28 to QSFP28 high-speed copper cable (supported in V200R024C00 and later versions, need a license loaded)

  • 10 m QSFP28 to QSFP28 AOC cable (supported in V200R024C00 and later versions, need a license loaded)

Remarque:

A QSFP+ optical port cannot be split into four 10GE ports.

In V200R024C00 and later versions, a RTU license can be loaded to increase the port rate to 100 Gbit/s.

The QSFP+ ports can work as 100GE ports after you activate the license, run the assign port-type 100ge [ fente slot-id | all ] command, and restart the switch.

3

Vis de terre

Remarque:
It is used with a ground cable.

4

Slot pour carte SSD

Remarque:

This slot is reserved for future use.

5

Un port de console

6

Un port de gestion ETH

7

Un port USB USB

8

Un bouton PNP

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

9

Fente de module de Fan 1

Remarque:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

10

Fente de module de Fan 2

Remarque:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

11

Fente de module de Fan 3

Remarque:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

12

Fente de module de Fan 4

Remarque:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

13

Emplacement de module de puissance 1

Remarque:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

14

Emplacement de module de puissance 2

Remarque:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

Port Description Description Description Description Description Description Description

10GE SFP+ optical port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-228 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-228 Attributes of a 10GE SFP+ port

Attribute

Description

Type de connecteur

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Mode fonctionnant

GE/10GE auto-sensing

40GE QSFP+ optical port

A 40GE QSFP+ optical port sends and receives service traffic at 40 Gbit/s. Table 4-229 describes the attributes of a QSFP+ optical port.
Table 4-229 Attributes of a QSFP+ optical port

Attribute

Description

Type de connecteur

MPO/LC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ba

Port Console

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-230.
Table 4-230 Attributes of a console port

Attribute

Description

Type de connecteur

RJ45

Standards compliance

RS-232

Mode fonctionnant

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Port de gestion ETH

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-231 describes the attributes of an ETH management port.
Table 4-231 Attributes of an ETH management port

Attribute

Description

Type de connecteur

RJ45

Standards compliance

IEEE802.3

Working Mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 m

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration.

Port USB

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

indicateur Description

Figure 4-95 Indicators on the S6730-S24X6Q
Table 4-232 Description of indicators on the switch

Non. Non.

Indicator

Nom et prénom

La couleur

État d’avancement

Description

1

système

Indicateur d’état du système

-

En dehors

Le système ne fonctionne pas.

vert

Clignotement rapide

Le système démarre.

vert

Stable sur

Pendant la phase de préparation au démarrage du système, l’indicateur SYS est vert constant, ce qui dure au maximum 30 secondes.

vert

Clignotement lent

Le système fonctionne normalement.

rouge

Stable sur

Le système ne fonctionne pas normalement après l’enregistrement, ou une alarme de ventilateur ou une alarme de température a été générée.

2

MST MST

Indicateur de cheminée

-

En dehors

L’interrupteur n’est pas l’interrupteur principal dans une pile.

vert

Clignant des yeux

L’interrupteur est l’interrupteur principal dans une pile ou un interrupteur autonome.

3

Carte d’identité

Indicateur d’identification

-

En dehors

L’indicateur ID n’est pas utilisé (état par défaut).

bleu

Stable sur

L’indicateur identifie le commutateur à entretenir. L’indicateur d’identification peut être allumé ou éteint à distance pour aider les ingénieurs de terrain à trouver l’interrupteur à entretenir.

4

-

Service port indicator (10GE optical port)

Remarque:

Chaque port optique a deux indicateurs de couleur unique. Celui de gauche est l’indicateur ACT (jaune), et celui de droite est l’indicateur LINK (vert).

Les flèches indiquent les positions des ports. Une flèche de bas indique un orifice en bas, et une flèche de haut indique un orifice en haut.

-

En dehors

Le port n’est pas connecté ou a été arrêté.

vert

Stable sur

Une liaison A été établie sur le port.

-

En dehors

Le port n’envoie ni ne reçoit de données.

jaune

Clignant des yeux

Le port envoie ou reçoit des données.

5

-

Service port indicator (40GE optical port)

Remarque:

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

-

En dehors

Le port n’est pas connecté ou a été arrêté.

vert

Stable sur

Une liaison A été établie sur le port.

Clignant des yeux

Le port envoie ou reçoit des données.

6

L/ d

Indicateur de port ETH

-

Off

Le port ETH n’est pas connecté.

vert

Stable sur

Le port ETH est connecté.

vert

Clignant des yeux

Le port Eth envoie ou reçoit des données.

7

USB

Indicateur de déploiement basé sur usb

-

Off

  • Aucun lecteur flash USB n’est connecté à l’interrupteur.

  • Le port USB est endommagé.

  • L’indicateur est endommagé.

  • Le lecteur flash USB ne possède aucun fichier de configuration et ne peut pas être utilisé pour le déploiement.

  • Le commutateur a été mis à jour à l’aide de la clé USB et redémarre.

vert

Stable sur

Un déploiement basé sur usb A été effectué.

vert

Clignant des yeux

Le système lit les données à partir d’une clé USB.

jaune

Stable sur

Le commutateur a copié tous les fichiers requis et terminé la vérification des fichiers. Le lecteur flash USB peut être retiré de l’interrupteur.

rouge

Clignant des yeux

Une erreur s’est produite lorsque le système exécute le fichier de configuration ou lit les données du lecteur flash USB.

Power Supply Configuration

The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Dissipation thermique

The S6730-S24X6Q uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Spécifications techniques

Table 4-233 lists technical specifications of the S6730-S24X6Q.

Table 4-233 Technical specifications

Article:

Description

Mémoire (RAM)

4 GB

Le Flash

2 go au total. Pour afficher la taille de la mémoire flash disponible, exécutez the Afficher la versionRe88pl99ace1command.

Temps moyen entre les défaillances (MTBF)

62,27 ans ans

Temps moyen de réparation (MTTR)

2 heures

disponibilité

> 0.99999-0.99999

Port de Service protection contre les surtensions

N/ d

Protection contre les surtensions d’alimentation électrique

  • Utilisation de modules de courant alternatif: ±6 kV en mode différentiel, ±6 kV en mode commun

  • Utilisation de modules d’alimentation cc: ±2 kV en mode différentiel, ±4 kV en mode commun

Dimensions (H x W x D)

  • Dimensions de base (à l’exclusion des parties dépassant du corps): 43,6 mm x 442,0 mm x 420,0 mm (1,72 po. X 17,4 po. X 16,5 po.)

  • Dimensions maximales (la profondeur est la distance entre les ports du panneau avant et la poignée du panneau arrière): 43,6 mm x 442,0 mm x 446,0 mm (1,72 po. X 17,4 po. X 17,6 po.)

Weight (with packaging)

8.9 kg (19.62 lb)

Ports de pile

  • Tous les ports 10GE SFP+ (un maximum de 16 ports physiques)

  • Tout 40GE QSFP+ ports (un maximum de 6 ports physiques)

Le CCF

Pris en charge

RPS:

Non pris en charge

PoE

Non pris en charge

Gamme de tension évaluée

  • Entrée ca: 100 V AC à 240 V AC, 50/60 Hz

  • Entrée haute tension DC: 240 V DC

  • Entrée DC: -48 V DC à -60 V DC

Plage de tension maximale

  • Entrée ca: 90 V ca à 290 V ca, 45 Hz à 65 Hz

  • Entrée haute tension DC: 190 V DC à 290 V DC

  • Entrée DC: -38.4 V DC à -72 V DC

Consommation d’énergie maximale

High temperature 45°C (113°F), 100% traffic, and dual power modules: 170 W

High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 249 W

Consommation électrique typique

30% traffic under the ATIS standard and dual power modules: 135 W

Température de fonctionnement

-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Remarque:

Lorsque l’altitude est de 1800-5000 m (5906-16404 pi.), la température de fonctionnement la plus élevée diminue de 1°C (1,8 °F) chaque fois que l’altitude augmente de 220 m (722 pi.).

L’interrupteur ne peut pas être démarrée lorsque la température ambiante est inférieure à 0°C (32°F).

Température de stockage

-40°C à +70°C

Bruit à température normale (27°C, puissance acoustique)

< 65 dB(A)

Humidité Relative

5% to 95%, noncondensing

Altitude de fonctionnement

0-5000 m (0-16404 pi.)

Certification:

  • Certification d’emc

  • Certification de sécurité

  • Certification de fabrication

Numéro de pièce

02353AJW

02353AJW-001

02353AJW-003

02353AJW-004


tag-icon Tags chauds: Interrupteurs Huawei

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.