Inscrivez-vous maintenant pour un meilleur devis personnalisé!

Huawei Switch S6700 Configuring the Traffic Statistics Interval

Jul, 08, 2024 Hi-network.com

Huawei Switch S6700 Configuring the Traffic Statistics Interval

Configuring the Traffic Count Interval

Informations générales

By configuring the traffic statistics interval function of an interface, users can count and analyze the messages of interest. At the same time, network congestion and service interruption can be avoided by checking the traffic statistics of the interface in advance and taking timely measures for traffic control.


 - When users find that the network is congested, they can set the interface's traffic statistics time interval to less than 300 seconds (30 seconds when congestion is intensified) voir aussi: and observe the interface's traffic distribution within a short period of time. For data messages that cause congestion, take flow control measures.


 - When the network bandwidth is sufficient and the business is running normally, you can set the traffic statistics interval of the interface to greater than 300 seconds. Once an abnormal traffic parameter is found, the traffic statistics interval is modified in time to facilitate more real-time observation of the trend of this traffic parameter.


Description Description

 - The traffic statistics interval configured in system view takes effect on all interfaces whose interval is the default value.


 - The traffic statistics interval configured in interface view takes effect only for this interface and does not affect other interfaces.


 - The interval configured in interface view has a higher priority than the interval configured in system view.


Procédure à suivre

 - To configure the global traffic statistics interval

1. Enter system view.

system-view

2. Configure the global flow-stat interval.

set flow-stat interval interval

By default, the global flow-stat interval is 300 seconds.


 - To configure the interface flow-stat interval

1. Enter system view.

system-view

2. Enter interface view.

interface { interface-name | interface-type interface-number }| interface-type interface-number }

3. Configure the interface flow-stat interval.

set flow-stat interval interval

By default, the interface flow-stat interval is 300 seconds.


Huawei S6700 Series Switches

For Huawei product list and quote, please contact us at www.hi-network.com  (Email: [email protected])

tag-icon Tags chauds: Interrupteurs Huawei

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.