The CloudEngine S6730-H-V2 series offers a range of next generation 10 GE routing switches with 24, 28, or 48 downlink ports plus 6 x 40 GE uplink ports — which can be expanded to 100 GE through licensing — and one extended slot.
Built on Huawei's unified software platform , the series offers a range of various Intent-Driven Network (Carte d’identitéN) voir aussi: features, including support for Virtual Extensible Local Area Network (VXLAN) technology, which builds one network for multiple purposes. Meanwhile, a free mobility feature ensures a consistent user experience.
The S6730-H28X6CZ-V2 is a next-generation enterprise-class core and aggregation switch designed to meet the evolving demands of modern networks. Part of Huawei's CloudEngine S6730-H-V2 series, this switch offers high performance, flexibility, and advanced features suitable for various networking scenarios.
The S6730-H28X6CZ-V2 boasts several notable features:
▪ High Le Port Density: Equipped with 28 x 10 GE SFP+ downlink ports and 6 x 40/100 GE QSFP28 uplink ports, providing ample connectivity options.
▪ Flexible Uplink Les Ports: Default 40 Gbit/s uplink ports can be upgraded to 100 GE through licensing, allowing for scalable network growth.
▪ Advanced VXLAN Support: Supports Virtual Extensible LAN (VXLAN) for network virtualization, enabling the creation of multiple virtual networks over a physical infrastructure.
▪ High Switching Capacity: En dehorsers a switching capacity of up to 2.4 Tbps, ensuring efficient data forwarding and minimal latency.
▪ rougeundant Power Supply: Features dual pluggable power modules with 1+1 redundancy, enhancing system reliability.
▪ Intelligent Stack (iStack): Supports iStack technology, allowing multiple switches to function as a single logical device for simplified management and enhanced scalability.
▪ Comprehensive Security Features: Includes various security mechanisms such as 802.1X authentication, MAC address filtering, and port security to safeguard network integrity.
▪ Energy Efficiency: Designed with energy-saving features to reduce power consumption without compromising performance.
▪ Robust Qualité de Service (QoS): Provides advanced QoS capabilities to prioritize critical traffic and ensure optimal performance for essential applications.
▪ Enhanced O&M: En dehorsers intelligent operations and maintenance features, including real-time monitoring and diagnostics, to simplify network management.
Below are the key technical specifications of the S6730-H28X6CZ-V2:Fixed Ports:28 x 10 GE SFP+
Uplink Ports:6 x 40/100 GE QSFP28
Extended Slots:1 extended slot
Switching Capacity:1.76 Tbps / 2.4 Tbps
Forwarding Performance:490 Mpps
Power Supply:Dual pluggable power modules, 1+1 redundancy
Dimensions (W x D x H):442 mm x 420 mm x 43.6 mm
Weight:7.06 kg
The S6730-H28X6CZ-V2 is versatile and can be deployed in various scenarios:
▪ Enterprise Campus Networks: Serves as a core or aggregation switch, providing high-speed connectivity and advanced features to support large-scale enterprise environments.
▪ Data Centers: Functions as a top-of-rack (ToR) or end-of-row (EoR) switch, offering high-density 10 GE ports and flexible uplink options for efficient data center networking.
▪ Service Provider Networks: Suitable for aggregation and core layers, delivering robust performance and scalability to meet the demands of service provider infrastructures.
The S6730-H28X6CZ-V2 is equipped with advanced networking features to enhance performance and flexibility:
The switch supports VXLAN L2 and L3 gateways, enabling the creation of virtualized networks over a shared physical infrastructure. This capability allows for the segmentation of network resources and supports multi-tenant environments.
With iStack technology, multiple S6730-H28X6CZ-V2 switches can be interconnected to form a single logical device. This simplifies network management and enhances scalability, allowing for seamless network expansion.
The switch offers robust security features, including:▪ 802.1X Authentication: Ensures that only authorized devices can access the network.
▪ MAC Address Filtering: Allows for the control of device access based on MAC addresses.
▪ Port Security: Protects against unauthorized access by limiting the number of valid MAC addresses allowed on a port.
The S6730-H28X6CZ-V2 simplifies network management and maintenance through:
▪ Cloud Management: Supports cloud-managed network services throughout the full lifecycle, from planning and deployment to monitoring and optimization.
▪ Intelligent O&M: Provides real-time monitoring, diagnostics, and analytics to proactively identify and resolve network issues.
▪ Unified User Management: Authenticates both wired and wireless users, ensuring a consistent experience across the network.
Designed with energy efficiency in mind, the S6730-H28X6CZ-V2 incorporates:
▪ Energy-Efficient Ethernet (EEE): Reduces power consumption during periods of low network activity.
▪ Intelligent Fan Control: Adjusts fan speed based on system temperature to minimize energy usage.
▪ Low-Power composants: Utilizes high-efficiency power supplies and components to decrease overall energy consumption.
The S6730-H28X6CZ-V2 provides advanced QoS features to ensure optimal performance for critical applications. It supports traffic classification, queue scheduling, and congestion control to prioritize essential data.
With flexible bandwidth management, network administrators can allocate resources efficiently, ensuring high-priority applications receive the necessary bandwidth while preventing congestion.
The switch minimizes delay with its high-performance forwarding architecture, making it suitable for latency-sensitive applications such as VoIP and video conferencing.
The S6730-H28X6CZ-V2 ensures network reliability with built-in redundancy and failover mechanisms:
▪ 1+1 Redundant Power Supply: Supports hot-swappable power modules for uninterrupted operation.
▪ Intelligent Link Backup: Automatically reroutes traffic in case of link failure to maintain connectivity.
▪ Loop Prevention Mechanisms: Supports STP, RSTP, and MST MSTP to prevent network loops.
This switch is ideal for a variety of network environments:
▪ Large Enterprises: Provides high-speed connectivity and security for large corporate networks.
▪ Service Providers: Acts as an aggregation or core switch in ISP and carrier networks.
▪ Government and Education: Supports secure and scalable networking solutions for institutions.
The Huawei S6730-H28X6CZ-V2 is a powerful, flexible, and feature-rich switch designed for modern networking needs. Its high-performance switching capacity, advanced security features, and energy-efficient design make it an excellent choice for enterprises, data centers, and service providers looking for a scalable and reliable solution.
Huawei CloudEngine S6730-H Switches
Huawei All Series Switches New and Used
For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com (Email: [email protected])
Table 4-27 Basic information about the S6730-H28X6CZ-V2
Article: | Détails détails |
---|---|
Description Description Description Description Description Description | S6730-H28X6CZ-V2 bundle (28*10GE SFP+ ports, 6*100GE QSFP28 ports, with license, 1*expansion slot, without power module) |
Numéro de pièce | 02354VCR |
modèle | S6730-H28X6CZ-V2 |
Première version supportée | V600R022C00 |
Remarques remarques | By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. |
Figure 4-10 S6730-H28X6CZ-V2 appearance
1 | Twenty-eight 10GE SFP+ optical ports | 2 | Six ports optiques 40GE/100GE QSFP28 Remarque:By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. |
3 | Un bouton PNP NOTICE:To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 4 | Vis de terre Remarque:It is used with a ground cable. |
5 | Card slot Remarque:In versions earlier than V600R024C00, this card slot is reserved. Applicable card: HSIC-X08S000 (available since V600R024C00 version) | 6 | Un port USB USB |
7 | Un port de gestion ETH | 8 | Un port de console |
9 | Fente de module de Fan 1 Remarque:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 10 | Fente de module de Fan 2 Remarque:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 | Fente de module de Fan 3 Remarque:Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 12 | Emplacement de module de puissance 1 Remarque:Applicable power modules:
|
13 | Emplacement de module de puissance 2 Remarque:Applicable power modules:
| - | - |
Table 4-28 Ports on the S6730-H28X6CZ-V2
Port | Type de connecteur | Description | Available Components |
---|---|---|---|
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
40GE/100GE QSFP28 optical port | QSFP28 | By default, the 100GE RTU license has been activated on the device, and QSFP28 ports work at the rate of 40 Gbit/s. You can run the active port-license and port mode 100GE interface commands to configure QSFP28 ports to work at 100 Gbit/s. In V600R023C10 and later versions, the last two 100GE ports can each be split into four 25GE ports using a command. The port can be automatically converted into four 10GE ports using one-to-four QSFP+ optical modules or AOC optical cables. |
|
Port Console | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
Port de gestion ETH | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. | Ethernet cable |
Port USB | USB 2.0 Type A | The USB port can have a Clé USB flash connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. | USB flash drive |
Figure 4-11 Indicators on the switchTable 4-29 Description of indicators on the switch
Non. Non. | Indicator | Nom et prénom | La couleur | État d’avancement | Description |
---|---|---|---|---|---|
1 | système | Indicateur d’état du système | - | En dehors | Le système ne fonctionne pas. |
vert | Clignotement rapide | Le système démarre. | |||
vert | Stable sur | Pendant la phase de préparation au démarrage du système, l’indicateur SYS est vert constant, ce qui dure au maximum 30 secondes. | |||
vert | Clignotement lent | Le système fonctionne normalement. | |||
Red | Stable sur | A fault that affects services has occurred and it cannot be rectified automatically (critical alarm about hardware). | |||
2 | MST | Indicateur de cheminée | - | En dehors | L’interrupteur n’est pas l’interrupteur principal dans une pile. |
vert | Clignant des yeux | L’interrupteur est l’interrupteur principal dans une pile ou un interrupteur autonome. | |||
3 | ID | Indicateur d’identification | - | En dehors | L’indicateur ID n’est pas utilisé (état par défaut). |
bleu | Stable sur | L’indicateur identifie le commutateur à entretenir. L’indicateur d’identification peut être allumé ou éteint à distance pour aider les ingénieurs de terrain à trouver l’interrupteur à entretenir. | |||
4 | - | Indicateur de port de Service (deux indicateurs pour chaque port) Remarque:Chaque port optique a deux indicateurs de couleur unique. Celui de gauche est l’indicateur ACT (jaune), et celui de droite est l’indicateur LINK (vert). Les flèches indiquent les positions des ports. Une flèche de bas indique un orifice en bas, et une flèche de haut indique un orifice en haut. | Meanings of service port indicators vary in different modes. For details, see Table 4-30 and Table 4-31. | ||
5 | - | Indicateur de port de Service (un indicateur pour chaque port) Remarque:Each optical port has one single-color indicator. Arrowheads show the positions of ports. | |||
6 | L/ d | Indicateur de port ETH | - | En dehors | Le port ETH n’est pas connecté. |
vert | Stable sur | Le port ETH est connecté. | |||
vert | Clignant des yeux | Le port Eth envoie ou reçoit des données. |
Table 4-30 Description of service port indicators in different modes (two indicators for each port)
Display Mode | La couleur | État d’avancement | Description |
---|---|---|---|
Default mode (LINK indicator) | vert | En dehors | Le port n’est pas connecté ou a été arrêté. |
vert | Stable sur | Une liaison A été établie sur le port. | |
Default mode (ACT indicator) | jaune | En dehors | Le port n’envoie ni ne reçoit de données. |
jaune | Clignant des yeux | Le port envoie ou reçoit des données. | |
Speed mode (LINK indicator) Remarque:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | En dehors | Le port n’est pas connecté ou a été arrêté. |
vert | Stable sur | 1GE/10GE SFP+ port: The port is operating at 1 Gbit/s. | |
vert | Clignant des yeux | 1GE/10GE SFP+ port: The port is operating at 10 Gbit/s. |
Table 4-31 Description of service port indicators in different modes (one indicator for each port)
Display Mode | La couleur | État d’avancement | Description |
---|---|---|---|
Default mode | - | Off | Le port n’est pas connecté ou a été arrêté. |
vert | Stable sur | Une liaison A été établie sur le port. | |
vert | Clignant des yeux | Le port envoie ou reçoit des données. | |
Speed mode Remarque:In V600R023C00 and later versions, the service port indicators can be set to the speed mode through the set device led mode Speed diagnostic command. The default mode is automatically restored after 45s. | - | Off | Le port n’est pas connecté ou a été arrêté. |
vert | Stable sur | 40GE/100GE QSFP28 port: The port is operating at 40 Gbit/s. | |
vert | Clignant des yeux | 40GE/100GE QSFP28 port: The port is operating at 100 Gbit/s. |
The switch can use a single power module or two power modules for 1+1 power redundancy. Les modules d’alimentation c.a. et c.c peuvent être utilisés ensemble dans le même interrupteur.
The switch uses pluggable fan modules for forced air cooling. Air flows in from the right and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Table 4-32 Technical specifications of the S6730-H28X6CZ-V2
Article: | spécification |
---|---|
Dimensions sans emballage (H x l x p) [mm(po.)] | Dimensions de base (à l’exclusion des parties dépassant du corps): 43,6 mm x 442,0 mm x 420,0 mm (1,72 po. X 17,4 po. X 16,54 po.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 455.0 mm (1.72 in. x 17.4 in. x 17.91 in.) |
Dimensions avec emballage (H x l x p) [mm(po.)] | 185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Hauteur du châssis [U] | 1 U U |
Chassis material | Metal |
Poids sans emballage [kg(lb)] | 7.06 kg (15.56 lb) |
Poids avec emballage [kg(lb)] | 10.04 kg (22.13 lb) |
Consommation électrique typique [W] | 203 W |
Dissipation thermique typique [BTU/ heure] | 692.66 BTU/hour |
Consommation d’énergie maximale [W] | 263 W |
Dissipation thermique maximale [BTU/ heure] | 897.38 BTU/hour |
Consommation électrique statique [W] | 136 W |
MTBF [années] | 52.24 years |
MTTR [heures] | 2 heures |
disponibilité | > 0.99999-0.99999 |
Bruit à température normale (puissance acoustique) [dB(A)] | 53.4 dB(A) |
Bruit à température normale (pression acoustique) [dB(A)] | 39.72 dB(A) |
Nombre de fentes pour cartes | 1 |
Nombre de emplacements de puissance | 2 |
Nombre de modules de ventilateurs | 3 |
Alimentation électrique redondante | 1+1 enfichables AC and DC power modules can be used together in the same switch. |
Température de fonctionnement à long terme [°C(°F)] | -5 °C à +45°C (23°F à 113°F) à une altitude de 0 à 1800 m (0 à 5905.44 pieds) |
Restriction du taux de variation de la température de fonctionnement [°C(°F)] | Lorsque l’altitude est de 1800-5000 m (5906-16404 pi.), la température de fonctionnement la plus élevée diminue de 1°C (1,8 °F) chaque fois que l’altitude augmente de 220 m (722 pi.). Les appareils ne peuvent pas démarrer lorsque la température est inférieure à 0°C (32°F). Lorsque le module optique QSFP-100G-ER4 est utilisé, la température de fonctionnement varie de -5°C à +40°C (23°F à 104°F). |
Température de stockage [°C(°F)] | -40 °C à +70°C |
Humidité relative de fonctionnement à long terme [RH] | 5% hr à 95% hr (sans condensation) |
Altitude d’exploitation à long terme [m(ft.)] | 0-5000 m (0-16404 pi.) |
Altitude de stockage [m(ft.)] | 0-5000 m (0-16404 pi.) |
Mode d’alimentation d’énergie | Alimentation électrique branchable |
Tension d’entrée nominale [V] |
|
Gamme de tension d’entrée [V] |
|
Courant d’entrée maximal [A] | Les spécifications actuelles sont liées au module d’alimentation enfichable. Pour plus de détails, voir Modules d’alimentation enfichables. |
La mémoire | 4 GB |
Mémoire Flash | Physical space: 2 GB |
Port Console | RJ45 |
Port de gestion Eth | RJ45 |
USB | Pris en charge |
Le CCF | Pris en charge |
Entrée RPS | Non pris en charge |
Port de Service protection contre les surtensions [kV] | - |
Protection contre les surtensions d’alimentation [kV] |
|
Niveau de protection contre les infiltrations (antipoussière/imperméable à l’eau) | IP20 - IP20 |
Types de ventilateurs | Pluggable |
Mode de dissipation thermique | Refroidissement à l’air pour la dissipation thermique, ajustement intelligent de vitesse de fan |
Direction du flux d’air | Air intake from front and right and air exhaust from rear |
PoE | Non pris en charge |
Certification: | Certification d’emc Certification de sécurité Certification de fabrication |